Case_Studies_V2_mini

To suit your needs, we take a very flexible approach in our structure and offer services ranging from half-day inspection visits to dedicated resident teams for several months or years.

Inspection Case Study : Resident Engineer

Inspection Case Study : Resident engineer

Inspection of equipments at ISGEC: A dedicated Baxcounsel inspector was resident for one year at ISGEC fabrication workshop at Yamunangar for providing inspection services for critical equipment

Item Design Code Shell ID Length Support height Design Pressure (bar) Design Temp. Material Weight
mm mm (Skirt / Saddle) max min max min (tonnes)
AGR Amine Drain Sump ASME VIII Div.I 3000 10,000 1900 / 1980 3.45 -0.6 145 4 A516 Gr. 60 103.6
Condensate Degasing Drum ASME VIII Div.I 4000 12,000 2250 3.45 175 120 A516 Gr. 60 213
Low Temp Separator PD5500.2003 Cat. 1 3400 4,750 3200 92 85 -92 BS 1501: 225 490BLT50 153
Deethaniser Reflux drum ASME VIII Div.I 2800 10,400 1650 31.5 85 -92 BS 1501: 225 490B 106
Depropaniser Reflux drum ASME VIII Div.I 2900 12,000 1650 24 85 46 A516 Gr. 70N 131
Refrigent Surge Drum ASME VIII Div.I 2600 12,100 1500 26 85 -46 A516 Gr. 70N 110
EGT Amine Drain Sump ASME VIII Div.I 2500 7,500 1512 3.45 175 150 A516 Gr.60N 52
1st Stage Mercaptan Extraction Vessel ASME VIII Div.I 4267 9,144 2400 18 175 85 A516 Gr. 70N 217
2nd Stage Mercaptan Extraction Vessel ASME VIII Div.I 4267 9,144 2400 18 175 85 A516 Gr. 70N 217
3nd Stage Mercaptan Extraction Vessel ASME VIII Div.I 4267 9,144 2400 18 175 85 A516 Gr. 70N 217
Propane Refrigirant Storage Drum ASME VIII Div.I 3400 11,000 1950 36 -0.5 85 -46 A516 Gr. 70N 191
Compressor Suction Separator PD5500.2003 Cat. 1 3200 4,830 2900 80 145 BS 1501: 225 490B 131
Compressor Inter Stage Separator PD5500.2003 Cat. 1 2700 4,540 2700 108 140 BS 1501: 225 490B 106